Amadis

C-4/AMERICAN EXPRESS Dynamic Reader Limits

Description

A Reader Limit Set is comprised of the following reader risk parameters as defined in Book C-4:

  • Reader Contactless Transaction Limit

  • Reader Contactless Floor Limit

  • Reader CVM Required Limit

DRLSET Configuration

TLV AMERICAN EXPRESS DRLSET (variable size)

TLV AMERICAN EXPRESS DRLSET (variable size)

Header

Version

unsigned char

Value between 0xAA and 0xAF

SHA-1

unsigned char[20]

SHA-1 calculation on the following data

EMV tag value

EMV length value

Comments

FF37

variable

DRLSet Configuration delimiter. FF37 length is equal to the length of all the following FF36

FF36

variable

DRL delimiter. FF36 length is equal to the length of the following TLV

DF23

6

Optional Reader Contactless Floor Limit

DF24

6

Optional Reader Contactless Transaction Limit

DF26

6

Optional Reader CVM Required Limit