Amadis

Particular Test Cases & Waivables

This section presents some ACE hints related to test cases executions that might lead to configuration errors.

See ACE Client to get more details on how to use ACE.

For RRP tests requiring a verification on Measure Relay Resistance Processing Time (Tag DF41), use the Log tab, with the Tag Log option in TMS→Administrative. This DF41 tag value must be divided by 10 for track2 value comparison.

  1. 3M06-9041(Term-On-Next-RA)

  2. 3M06-9050(FailRR-Stop)

These 2 tests are failed. This is due to the first read record emulated response containing errors, detected by the Kernel. So with a sequential processing, the kernel is not sending the next Read Record command. These 2 tests are waived

 

3B03-0001(A_03_TrxType-88)

For this one you have to uncheck the Transaction type checkbox and set it manually in Other TLVs section:

image-20240423-171053.png