The Reader Controller is a plugin in ACE-Client. It appears in Setup page as “Visa Automation”.

It starts the tests by exchanging a Transaction Configuration (STXN) and sends the Transaction Outcome (ETXN) at the end of the transaction.

Settings

Field

Comment

Address

Any valid IP address

Test Tool's IP address

Port

Any valid IP port

Test Tool's IP port

Actions/Buttons

Prepare

Prepares the Acceptance System before a session. The TERMINAL, PROCESSING configurations and the CAKeys are sent to the Acceptance System.

ECHO

Sends an ECHO administrative message to the Test Tool in order to check if the module can reach the Test Tool.

START

Executes one or several tests according to the number in the box on the right of the button. If the box contains 0 or 1, one test is executed. If the box contains a number greater than 1, executes that number of tests.

Reset

Reset the internal state of the Reader Controller if the state is blocked. To be used mainly if the Acceptance System does not answer to the payment request.

Administrative

Field

Value to be forced

Contactless

1

Signal

1

APDU Log

1

Legacy Visa

1

Digital Signals

1

The reader controller expects to receive at least the APDU responses and the signals in order to send the proper information in ETXN exchange.

Steps

  1. Define the Address and the Port of the Test Tool

  2. Prepare the Acceptance System

  3. Update the Administrative settings on Acceptance System according to the wiki

  4. Send the ECHO request to check if the communication with the Test Tool is working

  5. Select the number of tests in the box between START and Reset

  6. Execute the test(s) with START

What is not supported

  • IRWIN

  • Exception File

  • DRL Set

  • Revocation List

  • Online ODA