Amadis

Get 1st Generate AC Response (36h)

The 1st Gen AC Performed Exit Condition forces L2 to Exit after getting the Response from the First GENERATE AC APDU Command

Exit Condition Response Parameters

The Parameters Returned by this Exit Condition are:

Tag

Size (bytes)

Type

M/O/C

Description

‘D2’

1

b

M

Exit Condition ID = 36h

‘C7’

1

b

M

Contact Card Technology = 40h

‘9F06’

5-16

b

M

Matching Terminal AID

‘95’

5

b

M

Terminal Verification Results (TVR)

‘9B’

2

b

M

Terminal Status Information (TSI)

‘9F37’

4

b

C

Unpredictable Number (Terminal)

‘9F27’

1

b

C

Cryptogram information Data (CID)

‘9F36’

2

b

C

Application Transaction Counter (ATC)

‘9F26’

8

b

C

Application Cryptogram (AC)

‘9F10’

0-32

b

C

Issuer Application Data (IAD)

RESUME L2 PAYMENT TRANSACTION Command Parameters

The RESUME L2 PAYMENT TRANSACTION Command Parameters are ignored for this Exit Condition