Mastercard Test Environment Interface (TEI) module drives ACE-Client automatically:

Mastercard Test Environment Interface (TEI) module does not change:

Activation

STEP #1 Intialization on Device

(warning) Before starting a TEI session, Mastercard CAKeys and the TERMINAL configuration must be sent manually:

  • CaKeys file is C:\Amadis\ACE-Client\Data\MASTERCARD\CAKeys CL MASTERCARD

  • TERMINAL configuration must be configured for Mastercard Contactless

The “Prepare” button is sending the same CAKeys and current TERMINAL configuration.

During the execution of automated tests, it is better to not manipulate ACE-Client. Between the tests, ACE-Client is fully available. Please use the File > Export mechanism to send the information about the last transaction for support request.

The Revocated keys C:\Amadis\ACE-Client\Data\MASTERCARD\REVOK CL MASTERCARD are needed for some of the tests and must be sent manually:

  • 3M25-7340(A_01_RID1-IssCert-revoc)

  • 3M25-7340(A_02_RID2-IssCert-revoc)

  • 3M25-7340(B_01_RID1-IssCert-revoc)

  • 3M25-7340(B_02_RID2-IssCert-revoc)

  • 3M25-7340(C_01_RID1-IssCert-revoc)

  • 3M25-7340(C_02_RID2-IssCert-revoc)

STEP #2: Check DLL Presence

...

STEP #3: ACE Client Settings

Field

Comment

Value

Port

Listening Port

The value should match the port from Test Environment Interface Tool (10172 by default)

Automatic Start

Activate/Deactivate the TEI server start when ACE-Client is started

0 or 1

Configuration Version

Select the version of TEI library

  • MCL v3.1.3 TAL2-Testing Env Aug2020

  • MCL v3.1.4 TAL2-Testing Env Dec2020

  • MCL v3.1.4 TAL2-Testing Env May2021 (select this one for MCL v3.1.4)

Select Directory

Local directory to use locally defined configurations. Should be left empty.

As for example ACE Client side:

...

STEP #4: Start Automation On Ace Client:

Then click on Automatic Start for starting the TEI as for example:

...

STEP #5 Check the TEI parameters

...

When clicking on Start TEI, this menu is displayed in EVAL tool:

...

Note that:

  • ACT is supported

  • CLEAN is supported

  • TEST_INFO is supported

  • STOP_ACK is supported

  • TEST_DATA is NOT supported

  • Config is supported

  • PCD Bypass is NOT supported

By clicking on Start TEI, this menu appears:

...

Eval probe may be disconnected:

...

And even if you reconnect the probe, the test is still failedfailing, then you have 2 options:

  1. close EVAL and restart it

...

  1. Stop TEI tool first, reconnect Probe, then restart TEI tool (EVAL->Tools->Start TEI)

How to change the listening port in ACE Client

  1. change the value in the field

  2. click on Update Port button

  3. click on Stop button

  4. click on Start button (same as Stop)

...

FIME’s EVAL and TEI

Amadis does not provide EVAL or Test Environment Interface tool. If you have any questions on them, please contact the provider of theses tools.