For RRP tests requiring a verification on Measure Relay Resistance Processing Time (Tag DF41), use the Log tab, with the Tag Log option in TMS→Administrative. This DF41 tag value must be divided by 10 for track2 value comparison.
3M06-9041(Term-On-Next-RA)
3M06-9050(FailRR-Stop)
These 2 tests are failed. This is due to the first read record emulated response containing errors, detected by the Kernel. So with a sequential processing, the kernel is not sending the next Read Record command. These 2 tests are waived
3B03-0001(A_03_TrxType-88)
For this one you have to uncheck the Transaction type checkbox and set it manually in Other TLVs section:
...