The Reader Controller is a plugin in ACE-Client for VISA ART VCPS2.2c. It appears in Setup page as “Visa Automation”.
...
Field | Comment | |
---|---|---|
Address | Any valid IP address | Test Tool's IP address |
Port | Any valid IP port | Test Tool's IP port |
Number of tests | An unsigned integer | the number of tests to be executed |
Delay between tests | An unsigned integer | the delay between two tests in seconds |
Send empty revok | Yes/No | send empty revocation to clear the list if no revocation is given by the test |
Contact Interface | Yes/No | Same value as ICS 1.1 Is contact interface supported? |
Actions/Buttons
Prepare
Prepares the Acceptance System before a session. The TERMINAL, PROCESSING configurations and the CAKeys are sent to the Acceptance System.
...
Sends an ECHO administrative message to the Test Tool in order to check if the module ACE-Client can reach the Test Tool.
START
...
Field | Value to be forced | ||
---|---|---|---|
Contactless | 1 | ||
Signal | 1 | APDU Log | 1 |
Legacy Visa | 1 | ||
Digital Signals | 1 |
The reader controller expects to receive at least the APDU responses and the the digital signals in order to send the proper information in ETXN exchange.
Steps
Define the Address and the Port of the Test Tool
Prepare the Acceptance System
Update the Administrative settings on Acceptance System according to the wiki
Send the ECHO request to check if the communication with the Test Tool is working
Select the number of tests in the box between START and Reset
Execute the test(s) with START
What is not supported
IRWIN
Exception File
Online ODA
Check also this page for the ICS : PayWave Reference ICS