...
It sends PROCESSING and ENTRY POINT configurations
Transactions are started on acceptance device
Signals are updated during the transactions
Activation
STEP #1 Intialization on Device
Before starting a TEI session, Mastercard CAKeys and the TERMINAL configuration must be sent manually:
...
During the execution of automated tests, it is better to not manipulate ACE-Client. Between the tests, ACE-Client is fully available. Please use the File > Export mechanism to send the information about the last transaction for support request.
...
STEP #2: Check DLL Presence
The TEI dll for ACE-Client is not included in the setup. If you have libMasterCardAutomation.dll please copy it into C:\Amadis\ACE-Client\plugins.
Once the dll is in plugins directory, a new section appears at the bottom of Setup page with the title Mastercard Automation.
...
STEP #3: ACE Client Settings
Field | Comment | Value |
---|---|---|
Port | Listening Port | The value should match the port from Test Environment Interface Tool (10172 by default) |
Automatic Start | Activate/Deactivate the TEI server start when ACE-Client is started | 0 or 1 |
As for example ACE Client side:
...
...
STEP #4: Start Automation On Ace Client:
Then click on Automatic Start for starting the TEI as for example:
...
STEP #5 Check the TEI parameters
...
Test Environment Interface (TEI)
Once the TEI Server is started in ACE-Client, TEI tool can connect to ACE-Client (here, FIME’s EVAL screen captures are presented). .
EVAL side using Tools->Start TEI:
...
When clicking on Start TEI, this menu is displayed in EVAL tool:
...
Note that:
CLEAN is supported
TEST_INFO is supported
...
Config is supported
By clicking on Start TEI, this menu appears:
...
TEI tool should connect to ACE-Client and the Connection status should be green:
...
(driving the Reader) in the Reader connection side, so we use a localhost or 127.0.0.1 address with the 10172 communication port
...
On ACE side nothing has to be changed. Follow this:
Test the connection with this button:
...
FAQ
Is TEI module started ?
If the button Start/Stop at the right of button 'Update Port' displays 'Stop', TEI module is up. If it displays 'Start', the module is down.
How to change the listening port in ACE Client
change the value in the field
click on Update Port button
click on Stop button
click on Start button (same as Stop)
...
FIME’s EVAL and TEI
Amadis does not provide EVAL or Test Environment Interface tool. If you have any questions on them, please contact the provider of theses tools.