Deactivate APDU Log (no apdu logging into Signals tab)
If PROCESSING optional message is displayed (see GPI/SPED/display.c), and ACE is used, or the device has a display, set UI Display = 0
Set Signal = 0 (no CL signals)
Set Key In = 0 (no possibility to stop the transaction using the red cancel button in the virtual Terminal or with the cancel key on the physical terminal)
See TMS/Administrative dialog.
EMV Configurations
...
For tests requiring the TVR, set Always Receipt = 1. The TVR is then displayed in the receipt (see Transaction Related Data tab)
For tests requiring “STOP Button”, set the Key In = 1. Stopping a transaction can be done with the physical CANCEL key on the terminal, or using the red CANCEL key in ACE Client
See TMS/Administrative dialog.
Library Loading
If dynamic linking, copy C-x library to /AGNOS directory and modify apps file consequently
If static linking, use _STATIC_LOADER_ (loader.c) and _STATIC_LINK_ (x_kernel_name.h) to generate the project