It sends PROCESSING and ENTRY POINT configurations
Transactions are started on acceptance device
Signals are updated during the transactions
Mastercard Test Environment Interface (TEI) module does not change:
the TERMINAL configuration
the CAKeys or Revocated keys from CAKEYS, EFL, and CRL
Activation
STEP #1 Intialization on Device
...
The “Prepare” button is sending these the same CAKeys and current TERMINAL configuration.
During the execution of automated tests, it is better to not manipulate ACE-Client. Between the tests, ACE-Client is fully available. Please use the File > Export mechanism to send the information about the last transaction for support request.
The Revocated keys C:\Amadis\ACE-Client\Data\MASTERCARD\REVOK CL MASTERCARD are needed for some of the tests and must be sent manually:
3M25-7340(A_01_RID1-IssCert-revoc)
3M25-7340(A_02_RID2-IssCert-revoc)
3M25-7340(B_01_RID1-IssCert-revoc)
3M25-7340(B_02_RID2-IssCert-revoc)
3M25-7340(C_01_RID1-IssCert-revoc)
3M25-7340(C_02_RID2-IssCert-revoc)
STEP #2: Check DLL Presence
...
STEP #3: ACE Client Settings
Field | Comment | Value |
---|---|---|
Port | Listening Port | The value should match the port from Test Environment Interface Tool (10172 by default) |
Automatic Start | Activate/Deactivate the TEI server start when ACE-Client is started | 0 or 1 |
Configuration Version | Select the version of TEI library |
|
Select Directory | Local directory to use locally defined configurations. Should be left empty. |
As for example ACE Client side:
...
STEP #4: Start Automation On Ace Client:
Then click on Automatic Start for starting the TEI as for example:
...
STEP #5 Check the TEI parameters
...
When clicking on Start TEI, this menu is displayed in EVAL tool:
...
Note that:
ACT is supported
CLEAN is supported
TEST_INFO is supported
STOP_ACK is supported
TEST_DATA is NOT supported
Config is supported
PCD Bypass is NOT supported
...