Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

(warning) VCAS tests the integration of the software in the hardware. It implies a huge constraint on transaction overall duration (see Polling timeout below).

Settings

Field

Comment

Value

Port

Listening Port

IP port between 50000 and 65535

Automatic Start

Activate/Deactivate the VCAS server start when ACE-Client is started

0 or 1

TTQ

Default value of the TTQ in the configurations

any valid TTQ value

Online Only

Defines if the acceptance system is online only

1 for online only

0 otherwise

Agnos v3.3

Defines the version of Agnos Framework

1 for framework 3.3

0 otherwise

Troubleshooting

If you need us to investigate anything related to VCAS, perform the test/transaction then:

...

  1. change the TMS/Administrative settings in acceptance system. The values in the table below are set/modified:

Field

Forced Value

Contactless

1

Trace Depth

6 for APDU log delay

Key In

0

Signal

1

Polling timeout

VCAS tool gives the value of the polling timeout

APDU Log

0 if Agnos v3.3 is ticked

1 for the other frameworks

PayPass Legacy

0

Amex Legacy

0

JCB Legacy

0

CUP Legacy

0

DPAS Legacy

0

Visa Legacy

1

Digital Signals

1

The other values may depend on the ICS.

...

If you want to manually stop the VCAS please use the Start/Stop button.

VCAS.C.002.00 is failing

For 'Online only' terminals, the test VCAS.C.002.00 is failing.

In order to achieve the ‘online only’ functionality, the Contactless Floor Limit (VCAS tag C007) default value is set to 0x00 00 00 00 00 00 instead of 0x00 00 00 00 80 00.