Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Mastercard Test Environment Interface (TEI) module drives ACE-Client automatically:

...

(warning) Before starting a TEI session, Mastercard CAKeys and the TERMINAL configuration must be sent manually:

  • CaKeys file is C:\Amadis\ACE-Client\Data\MASTERCARD\CAKeys CL MASTERCARD

  • TERMINAL configuration must be configured for Mastercard Contactless

The “Prepare” button is sending these CAKeys and current TERMINAL configuration.

During the execution of automated tests, it is better to not manipulate ACE-Client. Between the tests, ACE-Client is fully available. Please use the File > Export mechanism to send the information about the last transaction for support request.

...

Field

Comment

Value

Port

Listening Port

The value should match the port from Test Environment Interface Tool (10172 by default)

Automatic Start

Activate/Deactivate the TEI server start when ACE-Client is started

0 or 1

Configuration Version

Select the version of TEI library

  • MCL v3.1.3 TAL2-Testing Env Aug2020

  • MCL v3.1.4 TAL2-Testing Env Dec2020

  • MCL v3.1.4 TAL2-Testing Env May2021

Select Directory

Local directory to use locally defined configurations. Should be left empty.

As for example ACE Client side:

...

  • CLEAN is supported

  • TEST_INFO is supported

  • TEST_DATA is NOT supported

  • Config is supported

  • PCD Bypass is NOT supported

By clicking on Start TEI, this menu appears:

...